A spill pallet is chosen by three parameters: sump capacity, load capacity and the size of the storage area. The sump capacity should hold the liquid that may leak from the stored containers – in practice at least the contents of the largest one. Confirm the exact requirement for your site in the applicable regulations and risk assessment.

What sump capacity is

Sump capacity is the volume of liquid the spill pallet will retain before it overflows. Do not confuse it with the external dimensions. Two spill pallets with a similar base can have very different capacities because their heights differ.

The general rule is simple: the spill pallet must retain a leak from a container that ruptures. So with a single container, the sump capacity should not be smaller than its volume. With several containers, their total volume is often taken into account too. Detailed thresholds depend on the type of substance and the regulations – check them before buying.

How to calculate the required capacity

  1. List the containers that will stand on the spill pallet and their volumes.
  2. Identify the largest container.
  3. Calculate the total volume of all containers.
  4. Check the requirements for the stored substance.
  5. Choose a spill pallet whose sump capacity meets the higher of the requirements.

Example: for 200 l drums, the “at least the largest container” rule means a spill pallet with a sump capacity of at least 200 l. This is met by e.g. WW2TS 232 l, WW4TS 250 l and WW3TS 250 l. For a 1000 l IBC tank you need a spill pallet above 1000 l, e.g. PW1TS 1120 l or PWIBC 1050 l.

Model comparison

ModelDimensions [mm]Sump capacityStatic loadIntended use per product page
PW3TS635×635×14045 lapprox. 567 kg1 drum, containers
PW4TS1245×635×14090 lapprox. 1134 kg2 drums
WWB11280×820×170100 lapprox. 1000 kgjerry cans, containers, with grid
WW1TS1600×800×150112 lapprox. 1350 kg2 drums
WWB1TS1310×910×380230 l–drums on a Euro pallet, without grid
WW2TS1600×1600×150232 lapprox. 2000 kg4 drums
WW3TS1300×750×440250 lapprox. 650 kgdrums, containers
WW4TS1380×1290×280250 lapprox. 1250 kg4 drums
PW1TS1450×1450×10001120 lapprox. 2000 kgIBC / KTC

Note the low spill pallets for several drums, e.g. WW1TS. They have a large surface area and load capacity, but a capacity smaller than one 200 l drum. They work well with smaller containers or where the requirements allow it.

With or without a grid

Spill pallet or spill deck

With many drums standing side by side, a spill deck can be used instead of individual spill pallets. For example, PR2KS has a capacity of 112 l and dimensions of 1410×760×140 mm, and PR4KS – 215 l at 1410×1410×140 mm. Both are made of HDPE. The capacity selection rule is the same as for spill pallets.

Typical mistakes

What else to look out for

You'll find the full range, including spill decks for drums, in the category spill pallets.

Frequently asked questions

What sump capacity should I choose for a 200 l drum?

Under the “at least the largest container” rule – a minimum of 200 l, e.g. WW2TS 232 l or WW4TS 250 l. Also check the requirements for your substance.

Which spill pallet for an IBC tank?

For a typical 1000 l IBC, choose a spill pallet with a sump capacity above 1000 l, e.g. PW1TS 1120 l or PWIBC 1050 l.

Can spill pallets be placed outdoors?

The product pages of many models, e.g. WW3TS, WW4TS and PW1TS, specify indoor storage. For outdoor use, ask us about a solution.

Can I connect several spill pallets?

Yes, e.g. WW1TS and WW2TS are joined with profiles and a connector into a larger work area. Details are given on the product pages.

Need help choosing?

Write or call – we'll recommend a model for your process and prepare a wholesale quote. Phone: +48 61 307 10 27, e-mail: biuro@paletyplastik.pl. PaletyPlastik.pl is the B2B shop of the PALETEO Group. Prices are net + VAT, we ship from our Bydgoszcz warehouse in 1–3 working days, and we accept orders from 1 piece (for some models the minimum is stated on the product page).