A spill pallet is chosen by three parameters: sump capacity, load capacity and the size of the storage area. The sump capacity should hold the liquid that may leak from the stored containers – in practice at least the contents of the largest one. Confirm the exact requirement for your site in the applicable regulations and risk assessment.
What sump capacity is
Sump capacity is the volume of liquid the spill pallet will retain before it overflows. Do not confuse it with the external dimensions. Two spill pallets with a similar base can have very different capacities because their heights differ.
The general rule is simple: the spill pallet must retain a leak from a container that ruptures. So with a single container, the sump capacity should not be smaller than its volume. With several containers, their total volume is often taken into account too. Detailed thresholds depend on the type of substance and the regulations – check them before buying.
How to calculate the required capacity
- List the containers that will stand on the spill pallet and their volumes.
- Identify the largest container.
- Calculate the total volume of all containers.
- Check the requirements for the stored substance.
- Choose a spill pallet whose sump capacity meets the higher of the requirements.
Example: for 200 l drums, the “at least the largest container” rule means a spill pallet with a sump capacity of at least 200 l. This is met by e.g. WW2TS 232 l, WW4TS 250 l and WW3TS 250 l. For a 1000 l IBC tank you need a spill pallet above 1000 l, e.g. PW1TS 1120 l or PWIBC 1050 l.
Model comparison
| Model | Dimensions [mm] | Sump capacity | Static load | Intended use per product page |
|---|---|---|---|---|
| PW3TS | 635×635×140 | 45 l | approx. 567 kg | 1 drum, containers |
| PW4TS | 1245×635×140 | 90 l | approx. 1134 kg | 2 drums |
| WWB1 | 1280×820×170 | 100 l | approx. 1000 kg | jerry cans, containers, with grid |
| WW1TS | 1600×800×150 | 112 l | approx. 1350 kg | 2 drums |
| WWB1TS | 1310×910×380 | 230 l | – | drums on a Euro pallet, without grid |
| WW2TS | 1600×1600×150 | 232 l | approx. 2000 kg | 4 drums |
| WW3TS | 1300×750×440 | 250 l | approx. 650 kg | drums, containers |
| WW4TS | 1380×1290×280 | 250 l | approx. 1250 kg | 4 drums |
| PW1TS | 1450×1450×1000 | 1120 l | approx. 2000 kg | IBC / KTC |
Note the low spill pallets for several drums, e.g. WW1TS. They have a large surface area and load capacity, but a capacity smaller than one 200 l drum. They work well with smaller containers or where the requirements allow it.
With or without a grid
- With a grid – containers stand above the liquid and a leak drains underneath. The grid is removed for cleaning. In the WW1TS, WW2TS and PW1TS models the grid is non-sliding and self-positioning.
- Without a grid – WWB1TS 230 l lets you put drums on a Euro pallet in place without reloading. Convenient for deliveries on pallets.
- With a drain plug – the WP 130 l spill pallet measuring 120×80×17 cm has a drain plug and forklift ramps.
Spill pallet or spill deck
With many drums standing side by side, a spill deck can be used instead of individual spill pallets. For example, PR2KS has a capacity of 112 l and dimensions of 1410×760×140 mm, and PR4KS – 215 l at 1410×1410×140 mm. Both are made of HDPE. The capacity selection rule is the same as for spill pallets.
Typical mistakes
- Choosing a spill pallet only by the number of drums, without checking the sump capacity.
- Exceeding the permissible static load with full containers.
- Not checking the plastic's resistance to the specific substance.
- Not pumping out the liquid after a leak – the spill pallet then loses capacity.
What else to look out for
- Chemical resistance – spill pallets are made of polyethylene or polypropylene. Check compatibility with a specific substance in the chemical's safety data sheet.
- Place of use – models such as WW3TS, WW4TS, WWB1TS and PW1TS are intended for containers stored indoors.
- Transport – most spill pallets have a base profile or ramps for a forklift.
- Connecting – WW1TS and WW2TS models can be joined into a larger work area using connecting profiles.
- Food industry – the WP2 and WP3 spill pallets (with an H1 pallet) are designed for plants with high hygiene requirements.
You'll find the full range, including spill decks for drums, in the category spill pallets.
Frequently asked questions
What sump capacity should I choose for a 200 l drum?
Under the “at least the largest container” rule – a minimum of 200 l, e.g. WW2TS 232 l or WW4TS 250 l. Also check the requirements for your substance.
Which spill pallet for an IBC tank?
For a typical 1000 l IBC, choose a spill pallet with a sump capacity above 1000 l, e.g. PW1TS 1120 l or PWIBC 1050 l.
Can spill pallets be placed outdoors?
The product pages of many models, e.g. WW3TS, WW4TS and PW1TS, specify indoor storage. For outdoor use, ask us about a solution.
Can I connect several spill pallets?
Yes, e.g. WW1TS and WW2TS are joined with profiles and a connector into a larger work area. Details are given on the product pages.
Need help choosing?
Write or call – we'll recommend a model for your process and prepare a wholesale quote. Phone: +48 61 307 10 27, e-mail: biuro@paletyplastik.pl. PaletyPlastik.pl is the B2B shop of the PALETEO Group. Prices are net + VAT, we ship from our Bydgoszcz warehouse in 1–3 working days, and we accept orders from 1 piece (for some models the minimum is stated on the product page).